Product Overview

Appropriate and effective emergency lighting systems are vital to facilitate occupant egress during an emergency, such as a building fire or other dangerous situation. In addition to prioritizing safety, proper emergency lighting is required by building codes such as NFPA 101, the Life Safety Code. Trust Eaton’s emergency lighting UPSs (10-200 kVA) to keep your occupants safe and your commercial structures up to code. Our emergency lighting UPSs (10-200 kVA) are UL 924 tested and certified, providing the industry’s highest capacity and smallest footprint options for emergency lighting applications.

Features & Benefits

  • UL 924 tested and certified to meet NFPA 101 (Life Safety Code) and other important building codes
  • An Eaton factory limited warranty, technical support and options for service and monitoring/management plans (PredictPulse) provide investment protection and peace-of-mind
  • Portfolio includes solutions that boast industry-leading efficiency with Eaton’s Energy Saver System (ESS) and small footprints
  • Standard accessories available with UL 924 systems including communications cards, maintenance bypasses and distribution cabinets

Eaton 9355 Emergency Lighting Technical Specifications

Information
UL 924 MarketEmergency
ConfigurationTower
Electrical Information
Electrical ConnectionsHardwired. See manual for terminal block layout.
Operating Frequency50/60 Hz
Input Power Factor> 0.99 typical
Input Current Distortion5% THD
Output Voltage Regulation±1% Static; ±5% dynamic at 100% resistive load change, <1 ms response time
Overload Capacity150% for 5 sec / 125% for 1 min (online), 110% for 10 min (Normal Operation)
Communications
Communication Ports(1) RS-232, (1) Relay Contact, (1) REPO, (2) Environmental Input
Communication Slot(2) X-Slot communication bays, where system provided with (1) gateway card factory installed
Environmental & Standards
Audible Noise<53 dBA @ 1 meter, typical
Operating Temperature10°C to + 40°C, +45°C with 7.5% derating; Batteries recommended max. +25°C
Safety MarkingsIEC62040-1:2008/A1:2013, UL 1778, UL 924
MarkingsUL, cULus
Quality and EnvironmentISO 9001:2008 and ISO 14001:2004
Storage Temperature-15°C to +25°C
Relative Humidity0-95%, non-condensing
Altitude<1000m at +40°C, <3000m at +25°C
Due to continuing improvements, specifications are subject to change without notice.

Eaton 9355 Emergency Lighting UPS Models

System RatingUnit DescriptionPart NumberQtyVoltageSystem Dimensions
(H x W x D, inches)
System Weight
(lb)
8.5 kVA/kWUPS
EBM
BH10KEL2083P100
BHEBM96EL600
1
2
208V three phase47.8 x 36 x 33.72029
13.1 kVA/kWUPS
EBM
BH15KEL2083P100
BHEBM96EL600
1
3
208V three phase47.8 x 48 x 33.72739
18 kVA/kWUPS
EBM
BH20KEL2083P100
BHEBC72EL600
1
2
208V three phase66 x 60 x 34.15280
24 kVA/kWUPS
EBM
BH30KEL208SF100
BHEBC72EL600
1
2
208V three phase66 x 60 x 34.15280
27 kVA/kWUPS
EBM
BH30KEL2083P100
BHEBC72EL600
1
3
208V three phase66 x 80 x 34.17340
18 kVA/kWUPS
EBM
XFMR
BH20KEL2083P100
BHEBC72EL600
BHKBT004200
1
2
1
480V three phase66 x 80 x 34.16072
24 kVA/kWUPS
EBM
XFMR
BH30KEL208SF100
BHEBC72EL600
BHKBT004200
1
2
1
480V three phase66 x 80 x 34.16072
24 kVA/kWUPS
EBM
XFMR
BH30KEL208SF100
BHEBC72EL600
BHKBT004200
1
3
1
480V three phase66 x 100 x 34.18132

Eaton 9355 Emergency Lighting Document Downloads