Serving Ohio's Critical Power needs for 30+ years
Appropriate and effective emergency lighting systems are vital to facilitate occupant egress during an emergency, such as a building fire or other dangerous situation. In addition to prioritizing safety, proper emergency lighting is required by building codes such as NFPA 101, the Life Safety Code. Trust Eaton’s emergency lighting UPSs (10-200 kVA) to keep your occupants safe and your commercial structures up to code. Our emergency lighting UPSs (10-200 kVA) are UL 924 tested and certified, providing the industry’s highest capacity and smallest footprint options for emergency lighting applications.
| UPS Rating (1.0 power factor) | ||||
| kW | 20, 30, 40, 50, 60, 70, 80, 90, 100, 110, 120, 130, 140, 150, 160, 170, 180, 190, 200 | |||
| General Characteristics | ||||
| Audible noise | 65 dBA at 200 kW | |||
| Altitude (max) | 1,500 meters / 4,922 feet | |||
| Scalability | Up to 4 internal power modules External parallel with up to 8 UPSs Interact with the 93PM to take a closer look |
|||
| Efficiency | 93PM efficiency with ESS- 99% 93PM double-conversion efficiency- up to 97% |
|||
| Input Characteristics | ||||
| Voltage | 480 (208 with IAC-D) | |||
| Voltage range | +10% / -10% | |||
| Frequency range | 50/60 Hz | |||
| Power factor | ≥ .99 | |||
| Input current distortion | <3% @ 100% load capacity | |||
| Soft start capability | Yes | |||
| Internal backfeed protection | Yes | |||
| Output Characteristics | ||||
| Voltage | 480 (208 with IAC-D) | |||
| Regulation | ±1% steady state | |||
| Inverter | PWM with IGBT Switching | |||
| Voltage THD | < 1% (100% linear load); < 5% (non-linear load) |
|||
| Load power factor range | .8 leading to .8 lagging without de-rating | |||
| Heat dissipation (BTU/Hr x 1000/Hr) |
20 kW, 480V: 2.55 30 kW, 480V: 3.58 40 kW, 480V: 4.56 50 kW, 480V: 5.70 60 kW, 480V: 7.16 70 kW, 480V: 8.36 80 kW, 480V: 9.12 90 kW, 480V: 10.26 100 kW, 480V: 11.40 110 kW, 480V: 12.54 |
120 kW, 480V: 13.68 130 kW, 480V: 14.82 140 kW, 480V: 15.96 150 kW, 480V: 17.10 160 kW, 480V: 18.24 170 kW, 480V: 19.38 180 kW, 480V: 20.52 190 kW, 480V: 21.66 200 kW, 480V: 22.80 |
||
| Battery | ||||
| Battery type | VRLA | |||
| Battery voltage | 480V | |||
| Charging method | ABM or float technology | |||
| Dimensions and Weights | ||||
| UPS Model | Height (mm/inches) | Width (mm/inches) | Depth (mm/inches) | |
| 93PM Auxiliary Lighting UPS – 50, 100, 150 frame | 1880/74 | 559/22 | 1067/42 | |
| 93PM Auxiliary Lighting UPS- 200 frame | 1880/74 | 813/32 | 1067/42 | |
| Serviceability | ||||
| Back/side against wall installation | Standard, front access only | |||
| Certification | ||||
| Safety | UL 924 Auxiliary Lighting | |||
| EMC | FCC Part 15 Subpart B Class A | |||
| Surge | IEC 61000-4-5 | |||
| Optional line and match accessories | ||||
|
||||
| eNotify Remote Monitoring service option | ||||
| 24×7 remote monitoring of UPS and battery alarms, daily heartbeat check and monthly report. eNotify requires the PXGX-UPS Card and Environmental Monitoring Probe | ||||
| Communication Options | ||||
| The following connectivity options can be installed at any time: | Power Xpert Gateway Mini-slot communication card Industrial relay card |
|||
Due to continuing improvements, specifications are subject to change without notice.